Boig & Hill, Inc. - Item # L93, L93 Loop-Powered Microprocessor- Controlled Positioner
Search Catalog
By Keyword
By Item #
All Categories
L93 Loop-Powered Microprocessor- Controlled Positioner
All Categories
>
Worcester Controls
>
Controls
>
Positioners
>
L93 Loop-Powered Microprocessor- Controlled Positioner
>
Item # L93
Item # L93 L93 Loop-Powered Microprocessor- Controlled Positioner
Printable Page
Email This Page
Save To Favorites
larger image
L93 Loop-Powered Microprocessor- Controlled Positioner
The positioner is programmed and calibrated using the five pushbuttons which are accessible when the aluminum cover is removed. Auto Calibration includes: • Leak Test • Air Delivery Optimization • Diagnostic Message Center Programming Options: • Basic, Advanced and Expert
Specifications
Features and Benefits
Maintenance Manual
L93 Installation, Operation and Maintenance Instructions
Circuitry
Loop-powered, not intrinsically safe
4L
Series
93
Actuator
Spring-Return
Double- Acting
Enclosures
Type 4x/IP66
Type 4x/IP66 Type 7
Limit Switches
None
2 SPDT mechanical switches
NAMUR sensors
Proximity (REED) switches
Input Signal
4-20mA mA
HART mA
Temperature Range
-22 to185
o
F
Temperature Range
-30 to 85
o
C
Weight
3 lbs.
Weight
1.4 kgs.
Air Supply
30 - 105 psi
Air Supply
2 - 7 bar
Air Delivery
13.8 SCFM
Air Delivery
400 nl/min
Air Consumption
< 0.3 nl/min
Air Connections (NPT)
1/4 inches
Cable Entry (NPT)
Three 1/2 inches
Two 1/2 inches
Electrical Connections
One 14-point terminal strip, 14-22 GA wire
One 8-point and one 3-point
Linearity
< 1%
Repeatability
< 0.5%
Hysteresis
< 0.4%
Dead Band
0.2–10% adjustable
Graphic Display Area
0.6x1.6 inches
Graphic Display Area
15x41 mm
HMI
5 push buttons
Processor
16 bit
CE Directives
93/68EEC, 89/336/EEC, 92/31/EEC
EMC
EN 50 081-2, EN 50 082-2
Voltage Drop
<10.1 V
Material
Die-cast aluminum, A2/A4 fasteners
Surface treatment
Power epoxy
Alarm output
1 k&Omega
Alarm Supply Voltage
8 - 28 V
Optional Switch Type
SPDT
Optional Switch Size
Sub Sub miniature
DC Voltage Range
5 -25 V
Optional Operating Time
0.7 ms
Optional NAMUR Sensors Type
Proximity DIN 19234 NAMUR
Optional NAMUR Sensors Load Current - for On
≤1 mA
Optional NAMUR Sensors Load Current - for Off
≥3 mA
Optional NAMUR Sensors Hysteresis
0.2%
Optional NAMUR Sensors Temp.
-4 to185
o
F
Optional NAMUR Sensors Temp.
-20 to 85
o
C
Optional Proximity Switch Type
SPDT
Optional Proximity Switch - Power Rating
5 W
Optional Proximity Switch - Current Rating
250 mA
Optional Proximity Switch - DC Voltage Rating
30 V
Optional Proximity Switch - AC Voltage Rating
125 V
Optional Proximity Switch - DC Breakdown Voltage
200 V
Optional Proximity Switch - Contact Resistance
0.1 &Omega
Optional Proximity Switch - Mechanical/Electrical Life
>50x10
6
operations
Optional Switch Current Rating for 125V AC
3 Amps
Optional Switch Current Rating for 30V DC
2 Amps
Optional 4-20 mA Transmitter- DC Supply Voltage
9 - 28 V
Optional 4-20 mA Transmitter- Output Current
4 - 20 mA
Optional 4-20 mA Transmitter- Resolution
0.1%
Optional 4-20 mA Transmitter- Linearity Full Span
± 0.5%
Optional 4-20 mA Transmitter- DC Output Current Limit
30 mA
Optional 4-20 mA Transmitter- Load impedance (at 24 DC Voltage)
800 &Omega
Special Options
None
Remote mount
4 - 20 mA output
MORE IMAGES
·
Internal Structure
·
Menu and Pushbuttons
·
Through-Cover Display Type 4X Enclosure
·
Through-Cover Display Type XP Enclosure
·
Explosion-Proof Enclosure
·
Piezoelectric Elements
·
Pneumatic Block
DOWNLOADS
L93 Installation, Operation and Maintenance Instructions
(PDF, 228KB)
L93
(PDF, 360KB)